Fire Testing Technology
Contact Us

Tel.: + 44 (0)1342 323600

Fax: + 44 (0)1342 323608

E-Mail: sales@fire-testing.com

Company Reg. No. 2387681

VAT Reg. No. 528 0253 63

A Judges Scientific plc Company

Terms and Conditions

 

Request quotation:

CLICK HERE >>>

SELECT BY: English French German Spanish Russian Simplified Chinese Traditional Chinese

LIFT, IMO Spread of Flame Apparatus

ISO 5658-2, IMO Resolution A.653(16), ASTM E 1317, ASTM E 1321

This instrument uses a gas-fired radiant heat panel with pilot flame ignition to ignite a test specimen.

Following ignition, any flame front which develops is noted and a record is made of the progression of the flame front horizontally along the length of the specimen in terms of the time it takes to travel to various distances.

The results are expressed in terms of the flame spread distance/time history, the flame front velocity versus heat flux, the critical heat flux at extinguishment and the average heat for sustained burning.

To meet the IMO specification a stack is fitted complete with thermopile for estimating heat release rate.

The apparatus is supplied with all necessary controls, flux meter and specimen holder.

The complete test apparatus consists essentially of three main components, a radiant panel support framework and a specimen support framework which are linked together to bring the test specimen into the required configuration in relation to the radiant panel, and the specimen holder, which carries the test specimen.

The radiant burner system is fully automatic, with spark ignition and safety interlocks.

 