{"id":1307,"date":"2019-02-17T13:43:09","date_gmt":"2019-02-17T13:43:09","guid":{"rendered":"https:\/\/www.fire-testing.com\/?page_id=1307"},"modified":"2022-08-05T12:22:03","modified_gmt":"2022-08-05T12:22:03","slug":"flame-propagation-test-for-a-single-insulated-cable","status":"publish","type":"page","link":"https:\/\/www.fire-testing.com\/es\/flame-propagation-test-for-a-single-insulated-cable\/","title":{"rendered":"Ensayo de propagaci\u00f3n de llamas para una cable aislado sencillo"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"1307\" class=\"elementor elementor-1307\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-0e3c60e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0e3c60e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-2d5468f\" data-id=\"2d5468f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-82af27e elementor-widget elementor-widget-heading\" data-id=\"82af27e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">Ensayo de propagaci\u00f3n de llamas para una cable aislado sencillo<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cfba1a4 elementor-widget elementor-widget-heading\" data-id=\"cfba1a4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">IEC \/ EN 60332-1-2<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f6f2b93 elementor-widget elementor-widget-text-editor\" data-id=\"2f6f2b93\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"translation-block\">Los ensayos EN 60332\u00ad1 y IEC 60332\u00ad1 de <span class=\"s1\"><span style=\"color: #f05e23\"><strong>FTT<\/strong><\/span><\/span> para la propagaci\u00f3n vertical de llamas de un alambre o cable aislado sencillo es un ensayo a escala de pruebas para determinar la resistencia de un cable sencillo ante la aplicaci\u00f3n de una llama de 1 kW. El aparato se suministra como un sistema completo que incorpora todas las caracter\u00edsticas necesarias para un uso sencillo de forma segura. Cumple con las normativas IEC\/ EN 60332\u00ad1\u00ad2 (propagaci\u00f3n de llamas) e IEC\/ EN 60332\u00ad1\u00ad3 (ensayo de gotas inflamadas).<\/p>\n<p class=\"translation-block\"><strong> IEC\/EN 60332-1 Aparato de ensayo <\/strong><br>\nLa norma IEC\/ EN 60332\u00ad1 utiliza una llama de ensayo con una altura y color espec\u00edficos, obtenida a partir de un gas suministrado a una contrapresi\u00f3n y velocidad de flujo determinados. Puesto que con estos aparatos <span style=\"color: #f05e23\"><strong>FTT<\/strong><\/span> se utilizan controladores de flujo, no se requiere ninguna contrapresi\u00f3n especial. Se coloca un sensor t\u00e9rmico por encima de la llama, y se determina el tiempo necesario para que la temperatura del sensor aumente desde 100 \u00baC hasta 700 \u00baC. Este tiempo se utiliza para confirmar el perfil de evoluci\u00f3n del calor en la llama de ensayo de 1kW.<\/p>\n<p class=\"translation-block\">El aparato <span style=\"color: #f05e23\"><strong>FTT<\/strong><\/span> IEC\/ EN 60332\u00ad1 consiste en una pantalla abierta montada sobre un banco equipada con un quemador encendido de forma el\u00e9ctrica, una unidad de control con enclavamientos de seguridad y ajuste del flujo de aire y de gas, y un panel desviador con controladores de las masas de aire y gas. Entre sus caracter\u00edsticas se incluyen:<\/p>\n<ul>\n<li>Soportes horizontales para las muestras<\/li>\n<li>Un quemador de conformidad con la norma EN 60695\u00ad11\u00ad2, con ajuste de \u00e1ngulo de la muestra de 90\u00ba a 45\u00ba, y sistema de seguridad para gases que solo permite que fluya el gas cuando se detecta una llama<\/li>\n<li>C\u00e1mara met\u00e1lica delantera abierta de 1200 mm de altura, 300 mm de anchura y 450 mm de profundidad<\/li>\n<li>Controladores de flujo m\u00e1sico para un control preciso y estable al quemador<\/li>\n<li>Encendido electr\u00f3nico por chispa<\/li>\n<li>Termopar de calibraci\u00f3n de conformidad con la norma EN 60695\u00ad11\u00ad2<\/li>\n<li>C\u00e1mara sin corrientes de aire opcional<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-467e41c\" data-id=\"467e41c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-69498e3 elementor-widget elementor-widget-image\" data-id=\"69498e3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/www.fire-testing.com\/wp-content\/uploads\/2019\/06\/08-Flame-Progation-Single-Wire_PIXEL-768x768.jpg\" class=\"attachment-medium_large size-medium_large wp-image-4194\" alt=\"Ensayo de propagaci\u00f3n de llamas para una cable aislado sencillo\" srcset=\"https:\/\/www.fire-testing.com\/wp-content\/uploads\/2019\/06\/08-Flame-Progation-Single-Wire_PIXEL-768x768.jpg 768w, https:\/\/www.fire-testing.com\/wp-content\/uploads\/2019\/06\/08-Flame-Progation-Single-Wire_PIXEL-150x150.jpg 150w, https:\/\/www.fire-testing.com\/wp-content\/uploads\/2019\/06\/08-Flame-Progation-Single-Wire_PIXEL-300x300.jpg 300w, https:\/\/www.fire-testing.com\/wp-content\/uploads\/2019\/06\/08-Flame-Progation-Single-Wire_PIXEL.jpg 800w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-840e81b elementor-widget elementor-widget-heading\" data-id=\"840e81b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">Ensayo de propagaci\u00f3n de llamas para una cable aislado sencillo<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-0432fba elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0432fba\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1d3f4f7\" data-id=\"1d3f4f7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"dce-visibility-event elementor-element elementor-element-2d9e2f5 elementor-widget elementor-widget-button\" data-id=\"2d9e2f5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;enabled_visibility&quot;:&quot;yes&quot;,&quot;dce_visibility_selected&quot;:&quot;yes&quot;}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.fire-testing.com\/es\/login\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">INICIE SESI\u00d3N\/REG\u00cdSTRESE PARA DESCARGAR ESTE FOLLETO<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"dce-visibility-event elementor-element elementor-element-d0964b5 elementor-widget elementor-widget-button\" data-id=\"d0964b5\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;enabled_visibility&quot;:&quot;yes&quot;,&quot;dce_visibility_selected&quot;:&quot;yes&quot;}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.fire-testing.com\/es\/request-a-brochure\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">REQUEST TECHNICAL SPECIFICATION<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<!-- dce invisible element d74478d -->\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Flame Propagation Test for a Single Insulated Cable IEC \/ EN 60332-1-2 The FTT EN 60332-1 and IEC 60332-1 tests for the vertical flame propagation of a single insulated wire or cable is a bench scale test to determine the resistance of a single cable to a 1kW flame application. The apparatus is supplied as [&hellip;]<\/p>\n","protected":false},"author":142,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-1307","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.fire-testing.com\/es\/wp-json\/wp\/v2\/pages\/1307","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fire-testing.com\/es\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fire-testing.com\/es\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fire-testing.com\/es\/wp-json\/wp\/v2\/users\/142"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fire-testing.com\/es\/wp-json\/wp\/v2\/comments?post=1307"}],"version-history":[{"count":0,"href":"https:\/\/www.fire-testing.com\/es\/wp-json\/wp\/v2\/pages\/1307\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.fire-testing.com\/es\/wp-json\/wp\/v2\/media?parent=1307"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}