{"id":788,"date":"2019-02-08T18:32:13","date_gmt":"2019-02-08T18:32:13","guid":{"rendered":"https:\/\/www.fire-testing.com\/?page_id=788"},"modified":"2022-08-08T09:37:38","modified_gmt":"2022-08-08T09:37:38","slug":"cone-corrosimeter","status":"publish","type":"page","link":"https:\/\/www.fire-testing.com\/zhcn\/cone-corrosimeter\/","title":{"rendered":"\u9525\u5f62\u8150\u8680\u8ba1"},"content":{"rendered":"<div data-elementor-type=\"wp-page\" data-elementor-id=\"788\" class=\"elementor elementor-788\" data-elementor-post-type=\"page\">\n\t\t\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-7533509 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7533509\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-bfcef1b\" data-id=\"bfcef1b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7e25595 elementor-widget elementor-widget-heading\" data-id=\"7e25595\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h1 class=\"elementor-heading-title elementor-size-default\">\u9525\u5f62\u8150\u8680\u8ba1<\/h1>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6004ad elementor-widget elementor-widget-heading\" data-id=\"e6004ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">ASTM D5485; ISO 11907-4<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1077be1e elementor-widget elementor-widget-text-editor\" data-id=\"1077be1e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p class=\"translation-block\">\u5f53\u4e0e\u9525\u5f62\u8150\u8680\u8ba1\u7ed3\u5408\u4f7f\u7528\u65f6\uff0c\u53ef\u4f7f\u7528\u9525\u5f62\u91cf\u70ed\u4eea\u548c\u8d28\u91cf\u635f\u5931\u91cf\u70ed\u4eea\u6765\u786e\u5b9a\u71c3\u70e7\u4ea7\u7269\u7684\u8150\u8680\u4f5c\u7528\u3002\u8981\u6267\u884c\u6b64\u64cd\u4f5c\uff0c\u5219\u6839\u636e\u6807\u51c6 (ASTM D5485; ISO 11907\u00ad4) \u534f\u8bae\uff0c\u901a\u8fc7\u4e00\u4e2a\u88c5\u6709\u94dc\u8150\u8680\u9776\u7684\u52a8\u6001\u66dd\u9732\u5355\u5143\u62bd\u53d6\u8be5\u4eea\u5668\u4e2d\u751f\u6210\u7684\u71c3\u70e7\u4ea7\u7269\u3002\u4f7f\u7528\u8150\u8680\u9776\u7684\u7535\u963b\u53d8\u5316\u6765\u8bc4\u4f30\u751f\u6210\u7684\u71c3\u70e7\u4ea7\u7269\u7684\u8150\u8680\u4f5c\u7528\u3002<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-c13f2d8\" data-id=\"c13f2d8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-53cc523 elementor-widget elementor-widget-image\" data-id=\"53cc523\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"768\" height=\"768\" src=\"https:\/\/fire-testing.com\/wp-content\/uploads\/2019\/02\/74-Cone-Corrosimeter-ASTM-D-5485-768x768.jpg\" class=\"attachment-medium_large size-medium_large wp-image-612\" alt=\"Cone Corrosimeter ASTM D5485\" srcset=\"https:\/\/fire-testing.com\/wp-content\/uploads\/2019\/02\/74-Cone-Corrosimeter-ASTM-D-5485-768x768.jpg 768w, https:\/\/fire-testing.com\/wp-content\/uploads\/2019\/02\/74-Cone-Corrosimeter-ASTM-D-5485-300x300.jpg 300w, https:\/\/fire-testing.com\/wp-content\/uploads\/2019\/02\/74-Cone-Corrosimeter-ASTM-D-5485-100x100.jpg 100w, https:\/\/fire-testing.com\/wp-content\/uploads\/2019\/02\/74-Cone-Corrosimeter-ASTM-D-5485-600x600.jpg 600w, https:\/\/fire-testing.com\/wp-content\/uploads\/2019\/02\/74-Cone-Corrosimeter-ASTM-D-5485-150x150.jpg 150w, https:\/\/fire-testing.com\/wp-content\/uploads\/2019\/02\/74-Cone-Corrosimeter-ASTM-D-5485.jpg 800w\" sizes=\"(max-width: 768px) 100vw, 768px\" \/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e832845 elementor-widget elementor-widget-heading\" data-id=\"e832845\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<p class=\"elementor-heading-title elementor-size-default\">\u9525\u5f62\u8150\u8680\u8ba1<\/p>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section data-particle_enable=\"false\" data-particle-mobile-disabled=\"false\" class=\"elementor-section elementor-top-section elementor-element elementor-element-b4f9836 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b4f9836\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b0db60c\" data-id=\"b0db60c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"dce-visibility-event elementor-element elementor-element-a7e67f0 elementor-widget elementor-widget-button\" data-id=\"a7e67f0\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;enabled_visibility&quot;:&quot;yes&quot;,&quot;dce_visibility_selected&quot;:&quot;yes&quot;}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.fire-testing.com\/zhcn\/login\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">\u767b\u5f55\/\u6ce8\u518c\u4ee5\u4e0b\u8f7d\u6b64\u624b\u518c<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"dce-visibility-event elementor-element elementor-element-7fad3fe elementor-widget elementor-widget-button\" data-id=\"7fad3fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;enabled_visibility&quot;:&quot;yes&quot;,&quot;dce_visibility_selected&quot;:&quot;yes&quot;}\" data-widget_type=\"button.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-button-wrapper\">\n\t\t\t\t\t<a class=\"elementor-button elementor-button-link elementor-size-sm\" href=\"https:\/\/www.fire-testing.com\/zhcn\/request-a-brochure\/\">\n\t\t\t\t\t\t<span class=\"elementor-button-content-wrapper\">\n\t\t\t\t\t\t\t\t\t<span class=\"elementor-button-text\">REQUEST TECHNICAL SPECIFICATION<\/span>\n\t\t\t\t\t<\/span>\n\t\t\t\t\t<\/a>\n\t\t\t\t<\/div>\n\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<!-- dce invisible element 5529c73 -->\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>","protected":false},"excerpt":{"rendered":"<p>Cone Corrosimeter ASTM D5485; ISO 11907-4 The Cone Calorimeter and Mass Loss Calorimeter can be used to determine the corrosive effect of combustion products when used with a cone corrosimeter. To do this in accordance with the Standards\u00a0 (ASTM D5485; ISO 11907-4) protocol the combustion products generated in the unit are drawn through a dynamic [&hellip;]<\/p>\n","protected":false},"author":142,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"class_list":["post-788","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/www.fire-testing.com\/zhcn\/wp-json\/wp\/v2\/pages\/788","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.fire-testing.com\/zhcn\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.fire-testing.com\/zhcn\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.fire-testing.com\/zhcn\/wp-json\/wp\/v2\/users\/142"}],"replies":[{"embeddable":true,"href":"https:\/\/www.fire-testing.com\/zhcn\/wp-json\/wp\/v2\/comments?post=788"}],"version-history":[{"count":0,"href":"https:\/\/www.fire-testing.com\/zhcn\/wp-json\/wp\/v2\/pages\/788\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.fire-testing.com\/zhcn\/wp-json\/wp\/v2\/media?parent=788"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}