Smoke Density Chamber (Horizontal Test): Conical Radiator Furnace

ISO 5659

The FTT smoke chamber has been designed specifically for potential modification to incorporate the ISO 5659 Conical Radiant Furnace which extends the potential of the NBS Smoke Chamber by allowing variable heat fluxes (up to 50 kW/m²), horizontal orientation of the specimen and the measurement of mass loss rate of the specimen. This also conforms with the recent IMO test protocols.

Overall Specifications:

  • Size (m): 1.90 (H) × 1.63 (L) × 0.66 (D)
  • Power Supply: 110/230 V - 50/60 Hz - 13 A
  • Size of actual chamber: 914 mm × 914 mm × 610 mm